Difference between revisions of "BMS"

From Saker
Jump to navigation Jump to search
m
m
Line 33: Line 33:
   
 
===RS485 bias termination===
 
===RS485 bias termination===
[[http://www.bb-elec.com/tech_articles/rs422_485_app_note/system_configuration.asp This]] page has a good rs485 2/4wire and termination description
+
[http://www.bb-elec.com/tech_articles/rs422_485_app_note/system_configuration.asp This] page has a good rs485 2/4wire and termination description
   
 
[[File:biasTermination.gif]]
 
[[File:biasTermination.gif]]

Revision as of 08:45, 27 November 2012

We are using the Tumanako EVD5 BMS

Saker specific BMS info:

The following pinout for the rs485 network does not appear to work. We believe the master is getting through to the slaves, in that they are responding, however there doesn't seem to be valid data returning to the terminal. Either that or the terminal is not receiving it correctly.

This data was derived from first principles on two separate occasions, ending in the same design. Either there is a subtle double negative, incorrect data supplied, or the port is not set up as necessary. A further test with oscilloscope is required.

RS485 pinout

Master Slaves
Signal JRMX EVD5
TX-1 1 2
TX+1 2 3
RX-1 4 5
RX+1 3 4
GND 5 1
5V - 6

JrMXrs485.png

EVD5Rs485Sch.png

RS485 bias termination

This page has a good rs485 2/4wire and termination description

biasTermination.gif