Connectors And Cabling
Jump to navigation
Jump to search
Emergency Disconnect Switch: The EVI200 system is supplied with main contactors. It's unclear if any additional equipment is required for emergency disconnection. Anderson disconnects or circuit breakers should be used when performing maintenance.
- Gigavac GX12 - a contactor that can almost do the job from the specs (gigavac have said that it will do the job via email).
- LEV200 - a contactor that will do the job according to specs
Connectors:
- http://www.andersonpower.com/products/multipole-sbe.html (700 amp connector will be needed for charging and inter pack connections - only rated at 150v(!), but tested to 1300v)
- http://www.multi-contact-usa.com (many different high current and voltage connectors)
Cabling:
- Lapp Kabel cables (site also has many connectors)
- General Cable NZ - welding cable (includes 600/1000V EPR/VNR)
- Wire size calculator at the bottom of the page
Fuses:
- LA100P300-4TI - Littelfuse 300A 750VDC
- FWJ 1000V - Bussman 300A 800VDC
Useful glossary of terms used in fuse specification sheets.
-- Main.PhilipCourt - 22 Dec 2007