Difference between revisions of "IPV5135 Motor"
Jump to navigation
Jump to search
(Imported from TWiki by twiki2mediawiki.py) |
(Imported from TWiki by twiki2mediawiki.py) |
||
Line 1: | Line 1: | ||
* [http://docs.google.com/Doc?id=dgb6fcnp_34dg4kjh Summary] |
* [http://docs.google.com/Doc?id=dgb6fcnp_34dg4kjh Summary] |
||
* [http://www.automation.siemens.com/ld/bahnen/html_76/elfa/elfa-10.html Siemens' Page] |
* [http://www.automation.siemens.com/ld/bahnen/html_76/elfa/elfa-10.html Siemens' Page] |
||
+ | |||
+ | == Thermal Considerations == |
||
+ | [http://www.proev.com ProEV] are running a pair of 5134WS20 motors with a pair of Simovert inverters. They have photos of the [http://proev.com/WHistPgs/Hist0022.htm cooling system] and a [http://proev.com/RRptPgs/R070004e.htm report] that it isn't very effective. They say that at 175C winding temperature, water exits the radiator at 40C and after motors and inverters, returns at only 46C. |
Revision as of 19:27, 11 February 2009
Thermal Considerations
ProEV are running a pair of 5134WS20 motors with a pair of Simovert inverters. They have photos of the cooling system and a report that it isn't very effective. They say that at 175C winding temperature, water exits the radiator at 40C and after motors and inverters, returns at only 46C.