Difference between revisions of "IPV5135 Motor"

From Saker
Jump to navigation Jump to search
(Imported from TWiki by twiki2mediawiki.py)
(Imported from TWiki by twiki2mediawiki.py)
Line 4: Line 4:
 
== Thermal Considerations ==
 
== Thermal Considerations ==
 
[http://www.proev.com ProEV] are running a pair of 5134WS20 motors with a pair of Simovert inverters. They have photos of the [http://proev.com/WHistPgs/Hist0022.htm cooling system] and a [http://proev.com/RRptPgs/R070004e.htm report] that it isn't very effective. They say that at 175C winding temperature, water exits the radiator at 40C and after motors and inverters, returns at only 46C.
 
[http://www.proev.com ProEV] are running a pair of 5134WS20 motors with a pair of Simovert inverters. They have photos of the [http://proev.com/WHistPgs/Hist0022.htm cooling system] and a [http://proev.com/RRptPgs/R070004e.htm report] that it isn't very effective. They say that at 175C winding temperature, water exits the radiator at 40C and after motors and inverters, returns at only 46C.
  +
  +
== Rotor Time Constant ==
  +
First guess at this value for our motor:
  +
  +
<pre>
  +
T2 = (L1h + L2sig)/R2
  +
  +
With:
  +
L1h = magnetizing inductance (H)
  +
L2sig = Rotor leakage inductance (H)
  +
R2 = Rotor resistance (H)
  +
  +
T = L/r = (L1h + L2sig)/R2
  +
=(6mH + 300 uH)/20mOhm
  +
=0.315 H/Ohm
  +
</pre>

Revision as of 17:16, 19 May 2010

Thermal Considerations

ProEV are running a pair of 5134WS20 motors with a pair of Simovert inverters. They have photos of the cooling system and a report that it isn't very effective. They say that at 175C winding temperature, water exits the radiator at 40C and after motors and inverters, returns at only 46C.

Rotor Time Constant

First guess at this value for our motor:

T2 = (L1h + L2sig)/R2

With:
L1h = magnetizing inductance (H)
L2sig = Rotor leakage inductance (H)
R2 = Rotor resistance (H)

T = L/r = (L1h + L2sig)/R2
=(6mH + 300 uH)/20mOhm
=0.315 H/Ohm